详细介绍:
LJ-108型吸枪式卤素检漏仪
灵迅LJ-108型吸枪式卤素检漏仪
是一款用于探测空调等制冷设备及系统冷媒泄漏的理想工具.其所能探测的冷媒范围包括R22,R23,R134a,R404a,R410a,R407c,R502等多种常用冷媒气体.
灵敏度高 反应迅速
其检测灵敏度达到0.5克/年,可精确地探测漏源.对烟雾,水蒸气等非冷媒气体无任何反应,避免误报警.快速反应时间保证了高效的检漏工作.当遇有大漏造成大量冷媒泄漏时,仪器能够迅速清除本底并立即回复测量状态.
操作方便 实用可靠
两米长的柔性吸枪可轻便地探测到所有漏点.通过面板上的按键可方便地预设漏率报警点,一旦检测到的漏率超过的警点,仪器将会发出报警声.仪器开机后便连续不断进行自检,遇有故障,红色LED指示灯将闪亮报警.内置冷媒气体漏源,可随时进行检漏功能测试.
技术先进 经久耐用
采用先进的红外技术制造的传感器,灵敏度高,使用寿命长,维护成本低.
技术指标:
可检气体
|
全部卤素 (R11,R12,R22,R23,R134a,
R404a,R410a,R407c,R502,R507等)
|
灵敏度
|
0.5 克/年
|
测量范围
|
0– 100克/年
|
响应时间
|
< 2 秒
|
传感器类型
|
红外
|
预热时间
|
约 1 分钟
|
电源电压
|
220伏 +/-10%, 50/60Hz
|
尺寸
|
260 x 285 x 150 毫米
|
重量
|
5.2 公斤
|
工作温度范围
|
10°C – 40°C
|
贮存温度范围
|
-20°C - 60°C
|
最大空气相对湿度
|
80%
|
LJ-108 type suction gun type halogen leak detector
Ling Xun LJ-108 type suction gun type halogen leak detector
Is the ideal tool for detecting such a air-conditioningrefrigeration equipment and system refrigerant leakage. It can detect refrigerant include R22, R23, R134a, R404a,R410a, R407c, R502 and other commonly usedrefrigerant gas.
High sensitivity, rapid response
The detection sensitivity up to 0.5 grams / year, can accurately detect the drain source. The smoke, noreaction of water vapor and other non refrigerant gas,avoid false alarm. Fast response time guarantees theleak detection work efficient. When there is a large leakcaused a lot of refrigerant leakage, instrument canquickly remove the bottom and immediately replymeasure.
The operation is convenient and practical and reliable
Flexible suction gun two meters long can be easilydetected all leak. Through the buttons on the front panelcan be preset leakage alarm, once detected leakage rate exceeds the alarm points, the instrument will alarm. The instrument on after continuous self, in case of failure, the red indicator light will be LED flashing alarm. The built-inrefrigerant gas leakage source, can leak test at any time.
Advanced technology and durable
The sensor, manufacturing of advanced infrared technology has the advantages of high sensitivity, long service life, low maintenance cost.
Technical indicators:
Test gas
All the halogens (R11, R12, R22, R23, R134a,
R404a, R410a, R407c, R502, R507 etc.)
Sensitivity
0.5 grams / year
Measuring range
0 - 100 grams / year
Response time
< 2 seconds
Sensor type
Infra-red
Preheating time
About 1 minutes
The power supply voltage
220 V +/-10%, 50/60Hz
Size
260 x 285 x 150 mm
Weight
5.2 kg
Operating temperature range
10 ° C - 40 ° C
Storage temperature range
-20 ° C - 60 ° C
The maximum relative humidity of the air
80%
|