Switching function
|
Normally open (NO)
|
Output type
|
PNP
|
Rated operating distance
|
8 mm
|
Installation
|
flush
|
Output polarity
|
DC
|
Assured operating distance
|
0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) )
0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) )
|
Reduction factor rAl
|
0.45
|
Reduction factor rCu
|
0.4
|
Reduction factor r304
|
0.7
|
Nominal ratings
|
Operating voltage
|
10 ... 30 V
|
Switching frequency
|
0 ... 500 Hz
|
Hysteresis
|
typ. 5%
|
Reverse polarity protection
|
reverse polarity protected
|
Short-circuit protection
|
pulsing
|
Voltage drop
|
≤ 3 V
|
Operating current
|
0 ... 100 mA
|
Off-state current
|
0 ... 0.5 mA typ. 0.1 μA at 25 °C
|
No-load supply current
|
≤ 15 mA
|
Switching state indicator
|
LED, yellow
|
Functional safety related parameters
|
MTTFd
|
2090 a
|
Mission Time (TM)
|
20 a
|
Diagnostic Coverage (DC)
|
0 %
|
Approvals and certificates
|
UL approval
|
cULus Listed, General Purpose
|
CSA approval
|
cCSAus Listed, General Purpose
|
CCC approval
|
CCC approval / marking not required for products rated ≤36 V
|
Ambient conditions
|
Ambient temperature
|
-40 ... 70 °C (-40 ... 158 °F)
|
Mechanical specifications
|
Connection type
|
Connector M12 x 1 , 4-pin
|
Housing material
|
brass, nickel-plated
|
Sensing face
|
PBT
|
Housing diameter
|
18 mm
|
Degree of protection
|
IP67
|