详细介绍: KEW3126绝缘电阻测试仪Insulation resistan
KEW3126绝缘电阻测试仪Insulation resistan
短路电流最大5mA。
测试量程范围从500V~5000V,最高可达1000GΩ。
PI (极化指数)和 DAR(诱电吸收比)。
条形图的大型数字显示屏以及背光灯。
滤波功能:减少干扰,可进行稳定测试。
输出电压和放电电压的显示。
自动放电功能和电压输出警告功能。
自动关机和电池检测功能。
面板贴牌采用荧光涂料,量程位置在黑暗中会发光,便于检测。
设计符合国际安全规格IEC61010-1 CAT.III600V。
Short circuit current biggest 5 ma.
Scope of testing range from 500 v to 500 v, up to 1000 g Ω.
Induced polarization index (PI) and DAR (electric absorption ratio).
The bar chart of the large digital display and backlight.
Filter function: to reduce disturbance, stability testing can be performed.
The output voltage and discharge voltage display.
The output voltage automatic discharge function and warning function.
Automatic shutdown and battery detection function.
Panel branded fluorescent paint, range position will glow in the dark, facilitate testing.
The design conforms to the international security specifications IEC61010-1 III600V.
量 程
|
绝缘电阻
|
电压测定
|
500V
|
1000V
|
2500V
|
5000V
|
V AC/DC
|
测定范围
|
0.0~99.9MΩ
100~999MΩ
|
0.0~99.9MΩ
100~999MΩ
1.00~1.99GΩ
|
0.0~99.9MΩ
100~999MΩ
1.00~9.99GΩ
10.0~99.9GΩ
|
0.0~99.9MΩ
100~999MΩ
1.00~9.99GΩ
10.0~99.9GΩ
100~1000GΩ(1TΩ)
|
30~600V
AC/DC
(50/60Hz)
|
精 确 度
|
|
|
|
|
|
短路电流
|
最大5.0mA
|
---
|
额定测定
电 流
|
0.5MΩ负荷时
1mA~1.2mA
|
1MΩ负荷时
1mA~1.2mA
|
2.5MΩ负荷时
1mA~1.2mA
|
5MΩ负荷时
1mA~1.2mA
|
---
|
开路电压
|
500VDC+30%
-0%以内
|
1000VDC+30%
-0%以内
|
2500VDC+30%
-0%以内
|
5000VDC+30%
-0%以内
|
---
|
最大显示
|
999计数(1000GΩ时1000计数)
|
630计数
|
消耗电流
|
约1000mA(测试中)
|
约110mA
|
耐 压
|
5320V/5秒 |
安全规格
|
IEC61010-1 CAT.III 600V 污染度 2 IEC61010-031 IEC61326
|
使用电池
|
LR14(12V)×8
|
外形尺寸
|
205(L)×152(W)×94(D)mm
|
重 量
|
约 1.8kg (含电池)
|
附 件
|
7165A(测试探棒)7224A(接地线)7225A(保护线)
9159(携带箱)8019(钩形探针)8254(延长探棒)
使用说明书、LR14(碱性电池)×8 校准书
|
可 选 件
|
7168A(鳄鱼夹测试线)8302(适配器) 7253(测试探棒)
|
|