详细介绍: Common Data
Mounting in steel shielded
Rated operating distance Sn 4mm
Assured operating distance Sa 0...3.2mm
Repeatability R <= 5%
Hysteresis <= 15%
Function indication yes
Ambient temperature range -25...+70°C
Polution Degree 3
IEC-Code I1A12AP2
Time delay before availability <= 10ms
Mechanical Data
Measurements BxHxT or DxT M12x1 x 50mm
Housing material nickel plated brass
Material of sensing face PA 12
Degree of protection IP67IP
Connection Connector S4
Schock: Halfsinus, 30 gn, 11ms
Vibration: 55 Hz, 1mm Amplitude, 3 x 30 Minutes
Electrical Data
Current type DC
Wiring 3-Wire
switching function normally-open
Output signal PNP
Rated opertional voltage 24 DCV
Rated opertional current 130mA
Supply voltage 10...30 DCV
Ripple <= 15% |